Download your free copy of the award winning ForPilots LogBook program today! |
In article <6OOr5.2354$qO1.211382@news.flash.net>, "johnlomack"
> Actually it comes from the alarm requirements of a Category I ILS. The > ground equipment is supposed to detect an out-of tolerance condition from > the radiated signal and shut it off within six seconds. (IIRC) nit: 6 seconds for glideslope Cat I, 10 seconds for LOC Cat I. -- Bob (I think people can figure out how to email me...) (replace ihatessppaamm with my name (rnoel) and hw1 with mediaone) |